Site:
Rose Bowl Stadium,
Pasadena, California

Problem:
For the renovation and expansion of new press boxes, it was discovered that a sandy gravel layer under the foundation would yield an unacceptable amount of settlement for the new structure.

Solution:
A permeation/chemical grouting system was used to solidify the sandy gravel layer into a solid mass to thwart future settlements.



PIER 45
ROSE BOWL
KOKORO
OFFICE
PLANT
HIGH-RISE

SERVICES
Compaction Grouting
The injection of grout into soil to achieve controlled displacement and densification of the surrounding soil mass and if needed proceed to controlled structural lifting.

Chemical Grouting
The injection of near-water-viscosity liquids into a cohesionless soil to react chemically and create an impervious solid mass, comparable to soft sandstone.